Adjusting Cable at Main Shut-Off Flap

-

Install heated air and fresh air blower controls

-

Turn blower rotary control onto stop at "0" position.

-

Push main shutoff flap lever onto stop (arrow) and secure cable sleeve.

Adjusting Cable at Temperature Flap

-

Install heated air and fresh air blower controls.

-

Turn temperature rotary control onto stop at "cold" position.

-

Push temperature flap lever onto stop (arrow) and secure blue cable sleeve.

Adjusting Cable at Footwell/Defrost Flap

-

Install heated air and fresh air blower controls.

-

Turn air distribution rotary control onto stop in defrost position.

-

Push footwell/defrost flap lever onto stop -arrow- and secure black cable sleeve.

Adjusting Cable at Center Flap

-

Install heated air and fresh air blower controls.

-

Turn air distribution rotary control onto stop in defrost position.

-

Push center flap lever onto stop -arrow- and secure black cable sleeve.

Securing Footwell/Defrost Flap to Control