Passat Sedan V6-3.6L (BLV) (2008)
‹› The HO2S Oxygen Sensor Bank 1 Sensor 2 (G130) fuse OK.
‹› Oxygen Sensor Heater Bank 1 Sensor 2 (Z29) OK.
‹› Battery voltage at least 12.5 volts.
‹› All electrical consumers such as, lights and rear window defroster, switched off.
‹› Vehicles with automatic transmission, selector lever in position " P" or "N".
‹› A/C switched off.
‹› Ground connections between engine/transmission/chassis OK.
‹› Exhaust system between catalytic converter and cylinder head properly sealed.
‹› Coolant Temperature at least 80° C.
Test procedure
-
Observe safety precautions. Refer to => [ Safety Precautions ] See: Service Precautions/Safety Precautions
-
Observe Clean Working Conditions. Refer to => [ Clean Working Conditions ] See: Service Precautions/Clean Working Conditions
-
Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check.
Function test
-
Perform the function test in Diagnostic Mode 06. Refer to => [ Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions ] See:
Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09.
-
Switch ignition off.
If the specified values are not obtained:
Start diagnosis
-
Disconnect the HO2S Oxygen Sensor Bank 1 Sensor 2 (G130) electrical harness connector - 1 -.