Passat Sedan V6-3.6L (BLV) (2008)
Variable Induction Control Actuator: Testing and Inspection
Intake Manifold Flap Vacuum Actuator, Checking
Intake Manifold Flap Vacuum Actuator, Checking
Special tools, testers and auxiliary items required
-
Hand vacuum pump VAS 6213 or hand vacuum pump V.A.G 1390
Conditions
-
Intake Manifold Runner Control (IMRC) valve N316 was checked using vehicle diagnosis, testing and information system VAS 5051 A under
"Guided Fault Finding".
Test Sequence
If Intake Manifold Runner Control (IMRC) valve N316 is OK
-
Disconnect vacuum hose at vacuum actuator.
When using the hand vacuum pump VAS 6213 :
-
Set the slide ring - 1 - on hand vacuum pump VAS 6213 to position - A - for "vacuum".
-
Connect hand vacuum pump to vacuum actuator - arrow -.
-
Operate hand vacuum pump several times. Operating plunger must move in - direction of arrow -.