Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check.

Start diagnosis

Checking internal resistance

-

Disconnect the HO2S Oxygen Sensor Bank 2 Sensor 2 (G131) electrical harness connector - 3 -.

-

Using a multimeter, check the Oxygen Sensor Heater Bank 2 Sensor 2 (Z30) terminals 1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the faulty HO2S Oxygen Sensor Bank 2 Sensor 2 (G131). Refer to the Repair Information.

If the specification was obtained:

Checking voltage supply

Start the engine.

-

Using a multimeter, check the Oxygen Sensor Heater Bank 2 Sensor 2 (Z30)electrical harness connector terminal 1 to ground for voltage.

Specified value: 10.10 to 11.70 V

Switch the ignition off.