Passat Sedan V6-3.6L (BLV) (2008)
Diagnostic Procedures
HO2S Rear Oxygen Sensor Bank 2 Sensor 2, Checking
‹› Vehicle must be raised before the electrical connector of the HO2S Oxygen Sensor Bank 2 Sensor 2 (G131) is accessible.
‹› When servicing terminals 3 and 4 in the electrical harness connector of the HO2S Oxygen Sensor Bank 1 Sensor 2 (G130) and HO2S Oxygen
Sensor Bank 2 Sensor 2 (G131), use only gold-plated terminals.
Special tools, testers and auxiliary items required
‹› multimeter.
‹› Wiring diagram.
Test requirements
‹› The HO2S Oxygen Sensor Bank 2 Sensor 2 (G131) fuses Ok.
‹› The Oxygen Sensor Heater Bank 2 Sensor 2 (Z30) OK.
‹› Battery voltage at least 12.5 volts.
‹› All electrical consumers such as, lights and rear window defroster, switched off.
‹› Vehicles with automatic transmission, selector lever in position " P" or "N".
‹› A/C switched off.
‹› Ground connections between engine/transmission/chassis OK.
‹› Exhaust system between catalytic converter and cylinder head properly sealed.
‹› Coolant Temperature at least 80° C.
Test procedure
-
Observe safety precautions. Refer to => [ Safety Precautions ] See: Powertrain Management/Computers and Control Systems/Service
Precautions/Safety Precautions
-
Observe Clean Working Conditions. Refer to => [ Clean Working Conditions ] See: Powertrain Management/Computers and Control
Systems/Service Precautions/Clean Working Conditions
-
Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check.
Function test