Passat Syncro Wagon V6-2.8L (ATQ) (2000)
Diagnostics/Oxygen Sensor Heater For Oxygen Sensors Before Catalytic Converter, Checking
Function test
-
Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output
of oxygen sensor signals. Refer to "Scan Tool Testing/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals" See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals
-
Check the specified values of the output of oxygen sensor signals at idle:
*) V = Voltage in Volts (oxygen sensor signal)
**) t = Time in seconds
Vehicles with engine code AHA