Passat Syncro Wagon V6-2.8L (ATQ) (2000)
Continuation for all vehicles
NOTE:
-
Cylinder bank 1 = in driving direction, right
-
Cylinder bank 2 = in driving direction, left
If specified values are obtained:
-
End diagnosis and switch ignition off.
If specified values are not obtained:
-
End diagnosis and let engine continue to run at idle.
-
Check primary voltage.
Checking primary voltage
-
Disconnect 4-pin harness connector to the respective oxygen sensor: