Passat Syncro Wagon V6-2.8L (ATQ) (2000)
Heated Oxygen Sensor (HO2S) 2 -G108-, bank 2 4-pin harness connector (black, arrow).
NOTE:
-
To reach this harness connector, remove coolant reservoir attachment screws and tilt coolant reservoir to the side. The coolant hoses remain
connected.
-
Bank 1 = Cylinder bank 1, in direction of travel, right
-
Bank 2 = Cylinder bank 2, in direction of travel, left
Vehicles with engine code AHA
-
Measure resistance for sensor heater at connector to oxygen sensor terminal 1 + 2.
Specified value: 0.0 to 19.9 Ohms
Vehicles with engine code ATQ
-
Measure resistance for sensor heater at connector to oxygen sensor terminal 1 + 2.
Specified value: max: 200 Ohms
Continuation for all vehicles
If specified value is not obtained:
-
Replace the respective oxygen sensor:
-
Heated Oxygen Sensor (HO2S) -G39-, bank 1, item 1
-
Heated Oxygen Sensor (HO2S) 2 -G108-, bank 2, item 15
-
Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.
-
Generate readiness code. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles