Switch on tester-arrow-.
Now the tester requires approx. 3 minutes to run up.
Reading ATF temperature
-
Switch on ignition.
-
Select mode of operation: press button on touch screen for "Vehicle self-diagnosis".
-
Select vehicle system: select "02. transmission electronics" on touch screen.
-
Interact with the system to confirm the control module number of the system selected.
-
Select diagnostic function: at this point, all diagnostic functions are available.
-
Select "08. read measured value blocks" on the touch screen.
-
Select display group 4 via "Measured value block" and "Change display group number".
The upper display zone shows the ATF temperature.
The ATF temperature should not be more than approx. 30° C at the start of the test.
-
Start engine.
-
Raise vehicle.
-
Place drip tray V.A.G 1306 underneath.
-
Bring ATF to test temperature.
Test temperature: 35°C to 45°C