◆ The fault table is listed according to the 5 digit fault code on the left.
◆ Explanation of the fault types (e.g. "open circuit/short circuit to earth"):
=> Fault reader operating instructions
◆ Before renewing components indicated as being faulty, check the wiring and connectors to these components as well as the earth connections using current flow diagram. This is particularly relevant if faults are output as "occurring sporadically" (SP).
◆ The faults displayed can be localised using the test table.
→
Fault reader print-out:
The number shown here in bold 035 (e.g.) has no relevance.
01463
035
Alarm via sensor for ATA system
V.A.G 1551 print-out
Possible fault cause
Fault elimination
00000
No fault recognised
If "No fault recognised" appears after carrying out repairs self-diagnosis is ended
65535
Control unit defective
- Control unit defective
- Replace control unit
01462
Anti-theft alarm ultra-sonic sensor -G209
Implausible signal
- Wiring or connections defective
- The ultra-sonic signal sequence is, at present, untypical for an ultra-sonic measurement (e.g. constant, or the signal is overall too high or too low)
- Anti-theft alarm ultra-sonic sensor -G209 defective
- Check wiring and connectors using current flow diagram
Renew anti-theft alarm ultra-sonic sensor -G209
V.A.G 1551 print-out
Possible fault cause
Fault elimination
01463
Alarm via sensor for ATA
This fault entry is an indication for the workshop, then an alarm has been triggered. Using measured value block 15 and the convenience system table it is possible to locate the area which triggered the system.
In addition the warning lamp in the deactivation button will flash for 1 minute.
- Read measured value block; Display group number 015
, display zone 1