| Briefly bridge connections between chambers -1- and -2- while engine is running. If the air conditioning system magnetic coupling -N25- switches on, the refrigerant circuit is empty. |
The switch part between chamber -3- and chamber -4- of the connector housing switches the radiator fan -V7- to the second speed via radiator fan control unit -J293- when the pressure in the refrigerant circuit rises. |
–
| Closes above 16 bar and opens below 12.5 bar (switching threshold). |
|
|
|