volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Measurements for evaluating air conditioning system > < Assembling tools and equipment
Evaluating test results
Evaluating test results
A workshop temperature of between 20° C to 30° C is assumed for the evaluation. The engine is at room temperature.
   
Test resultPossible cause of faultRectifying fault
Duty cycle of 20% to 25%High pressure sender -G65- is OK 
Duty cycle 90%High pressure sender -G65- defective
–  Renew high pressure sender -G65- → Chapter.
Duty cycle 5%
t  High pressure sender -G65- defective
or
–  Renew high pressure sender -G65- → Chapter.
 
t  Refrigerant circuit is empty
–  Charge with refrigerant.
Duty cycle 0%Short circuit or open circuit in wiring or connectors
–  Check wiring and connections according to current flow diagram.

  Note
If the cause of the customer complaint has not been found, check fault memory of engine electronics control unit.
   

Measurements for evaluating air conditioning system > < Assembling tools and equipment