Fault table: Fault codes 00515...01282 > < Erase fault memory
Automatic test sequence
Automatic test sequence
During test and assembly work faults can be recognised from other control units like e.g. plug disconnected. Therefore on completion the fault memories of all control units must be interrogated and erased. To do this:
–  Press button 0 twice for address word “Automatic test sequence” and confirm entry with Q button. The fault reader -V.A.G 1551- transmits all known address words one after the other.
When a control unit answers with its identification the number of stored faults appears on the display or “No fault recognised”.
Any system faults that are stored will be displayed one after the other and printed out. The fault reader -V.A.G 1551- will then transmit the next address word.
   
The automatic test sequence has ended when following is indicated on display: → Note
 
V.A.G SELF-DIAGNOSIS                HELP
1 - Rapid data transfer*              
or
1)  Appears alternately
–  Erase all fault memories and then carry out a road test.
–  Again interrogate the fault memories of all control units using the“automatic test sequence”. No faults must be stored in fault memory.
If no fault is stored:
–  Press the button.
 
V.A.G SELF-DIAGNOSIS                HELP
2 - Flash code output*                
Indicated on display:
–  Press buttons 0 and 6 for function “End output” and confirm entry with Q button.
 
Rapid data transfer                 HELP
Select function XX                      

Fault table: Fault codes 00515...01282 > < Erase fault memory