| Pull vent hose -1- from fuel tank off activated charcoal filter -2-. |
–
| Then connect hand vacuum pump -V.A.G 1390- and vacuum tester -V.A.G 1368- as shown to hose -1-. |
–
| Set vacuum tester to -A/B- position. |
–
| Remove fuel filler cap. |
–
| Operate hand-operated vacuum pump -V.A.G 1390- several times. Vacuum must not build up. |
–
| Check gravity/overflow valve → Item. |
–
| Check line -1- from fuel tank for free-flow. |
If vacuum does not build up: |
–
| Operate hand-operated vacuum pump -V.A.G 1390- several times. Vacuum must not build up. |
Note If fuel level in tank is low the hand vacuum must be operated at least 20...30 times. |
|
|
|