Evaluation: Display group 16, display zone 3 - actuation of heater elements > < Display group 016 at idling
Evaluation: Display group 16, display zone 2 - additional heater
Evaluation: Display group 16, display zone 2 - additional heater
  Note
Significance of figures in 8-digit number block for additional heater:
   
Significance if display = 1
xxxxxxxxAdditional heater switched off, because:
       1Coolant temperature greater than 70°C...80°C or intake manifold temperature greater than + 5°C
      1 Alternator -C- defective
     1  Battery voltage below 9 V
    1   Engine speed below 875 rpm
   1    Engine started within the last 10 seconds
  1     Coolant temperature sender -G62- or
intake manifold temperature sender -G72- defective
 1      Ignore
1       Ignore

   

Evaluation: Display group 16, display zone 3 - actuation of heater elements > < Display group 016 at idling