volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Evaluating measured value blocks > < Safety precautions
Read measured value block
Read measured value block
Special tools and workshop equipment required
t  Fault reader -V.A.G 1551- or vehicle system tester -V.A.G 1552- with diagnosis cable -V.A.G 1551/3-
Test prerequisites
   
l  Fuses must be OK.
l  Strip fuses in fuse box/battery OK.
l  The battery voltage must be at least 11.5 V.
l  Earth connections between engine and body must be OK.
l  All electrical consumers such as e.g. rear window heating must be switched off.
l  No faults must be stored in fault memory → Chapter, interrogating fault memory.
l  Coolant temperature must be at least 80°C, ⇒ display group 001, display zone 4.
Procedure
–  Connect fault reader -V.A.G 1551- or vehicle system tester -V.A.G 1552- and select engine electronics control unit with “address word 01”. Engine must be idling. (Connecting fault reader -V.A.G 1551- and selecting engine electronics control unit → Chapter).
  N24-0831
Indicated on display:
–  Press keys 0 and 8 for function “Read measured value block” and confirm entry with Q key.
 
Rapid data transfer                 HELP
Select function XX                    
Indicated on display:
  Note
The display group number 001 is an example to illustrate the sequence.
–  Press keys 0, 0 and 1 for “Display group number 1” and confirm entry with Q key.
 
Read measured value block                     
Input display group number XXX       
Indicated on display: (1...4 = display zones)
  Note
To change to another display group proceed as follows:
 
Read measured value block 1          ->
        1         2         3          4
Display groupFault reader -V.A.G 1551-Vehicle system tester -V.A.G 1552-
HigherPress key 3Press key
LowerPress key 1Press key
SkipPress C keyPress C key

–  If the specifications are achieved in all display zones, press key.
   
Indicated on display:
–  Press keys 0 and 6 for function “End output” and confirm entry with Q key.
–  Switch off ignition.
 
Rapid data transfer                 HELP
Select function XX                    

Evaluating measured value blocks > < Safety precautions