volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Definitions > < Test table (test steps 1 - 16)
Running gear self-diagnosis for ABS
Electrical check of ABS/EDL/TCS/ESP ITT Mark 20 IE
Test table (test steps 17 - 28)

Switch to measuring range:
Voltage measurement (20 V =) in test step 17, resistance measurement (200 ω)/(20 M ω)in test step 17a

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

17

-

Voltage supply for steering angle sender -G85

▪ Ignition switched off
Disconnect connection from steering angle sender -G85

- Disconnect multi-pin connection T47 from control unit -J104

- Check wiring between contact T6a/4 and connector contact T6a/1 of steering angle sender -G85

10.0 - 14.5 V

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 17: Continued on next page.

Continuation of test step 17

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

17

-

Voltage supply for steering angle sender -G85

- Ignition switched on
Check wiring between contact T6a/5 and connector contact T6a/1 of steering angle sender -G85

10.0 - 14.5 V

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 17a: On next page.

Continuation of test step 17a

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

17a

-

Wiring for steering angle sender -G85

▪ Set to measuring range 200 ω
Connect test box V.A.G 1598/33

- Check wiring for open circuit between steering angle sender -G85- and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 17a: On next page.

Continuation of test step 17a

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

17a

Wiring for steering angle sender -G85

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

18

-

Wiring for lateral acceleration sensor -G200

▪ Ignition switched off
▪ Set to measuring range 200 ω
Disconnect connection from lateral acceleration sensor -G200

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between lateral acceleration sensor -G200- multi-pin connector and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 18: Continued on next page.

Continuation of test step 18

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

19

-

Wiring for yaw rate sender -G202

▪ Ignition switched off
▪ Set to measuring range 200 ω
Disconnect connection from yaw rate sender -G202

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between yaw rate sender -G202- multi-pin connector and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 19: Continued on next page.

Continuation of test step 19

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

20

-

Wiring for brake pressure sender 1 -G201

▪ Ignition switched off
▪ Set to measuring range 200 ω
Disconnect connection from brake pressure sender 1 -G201

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between brake pressure sender 1 -G201- multi-pin connector and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 20: Continued on next page.

Continuation of test step 20

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

21

-

Wiring for brake pressure sender 2 -G214

▪ Ignition switched off
▪ Set to measuring range 200 ω
Disconnect connection from brake pressure sender 2 -G214

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between brake pressure sender 2 -G214- multi-pin connector and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 21: Continued on next page.

Continuation of test step 21

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

22

-

Wiring for brake pressure solenoid -N247

▪ Ignition switched off
▪ Set to measuring range 200 ω
Separate multi-pin connection T5 on brake servo

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between connector T5 for brake pressure solenoid -N247- and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 22: Continued on next page.

Continuation of test step 22

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

- Reconnect multi-pin connector T5 on brake servo
Separate multi-pin connection T14

- Check contacts 7 and 8 to brake pressure solenoid valve -N247- in multi-pin connector T14

1.0...4.0 kω

- Renew brake servo of specifications are not achieved

Test step 22: Continued on next page.

Continuation of test step 22

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

23

-

Wiring for brake pressure solenoid trip switch -F84

▪ Ignition switched off
▪ Set to measuring range 200 ω
Disconnect multi-pin connection T5 on brake servo

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between multi-pin connector T5 for brake pressure solenoid trip switch -F84- and control unit -J104- multi-pin connector

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 23: Continued on next page.

Continuation of test step 23

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

24

19 or 20

Data bus wiring

▪ Ignition switched off
▪ Set to measuring range 200 ω

- Disconnect multi-pin connection from a control unit which is connected via data bus wiring:

- Connect test box V.A.G 1598/33

- Check data bus wiring for open circuit

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 24: Continued on next page

Continuation of test step 24

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Voltage measurement (20 V =)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

25

-

Voltage supply for V.A.G 1551, connector T161)

▪ Ignition switched off
Connect multimeter V.A.G 1526 to connector T161)using adapter set V.A.G 1594

10.0 -14.5 V

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

1)     Diagnosis connection contact assignment =>Page 01-406

Switch to measuring range:
Resistance measurement 200 ω

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

26

-

Resistance of K wire for V.A.G 1551, connector T161)

▪ Ignition switched off
Disconnect multi-pin connection from control unit -J104

max. 1.5 ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

- Connect test box V.A.G 1598/33

- Connect multimeter V.A.G 1526 to contacts T16/71) and T47/39 of multi-pin connectors from control unit -J104- using cables from adapter set V.A.G 1594

1)     Diagnosis connection contact assignment =>Page 01-406

Switch to measuring range:
Resistance measurement (200 ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

27

2 + 30

Coding bridge

▪ Ignition switched off

0.0 -1.0 ω

8 + 21

Coding bridge

▪ Ignition switched off

0.0 -1.0 ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Switch to measuring range:
Voltage measurement (20 V =)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

28

-

Voltage supply for brake light suppression relay -J508

▪ Ignition switched off
Pull brake light suppression relay -J508- off additional relay carrier

- Check wire between contact 6/85 on additional relay carrier of deactivating brake light relay -J508- and vehicle earth

10.0 - 14.5 V

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 28: Continued on next page.

Continuation of test step 28

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

28

▪ Ignition switched off
▪ Brake pedal not depressed


- Read measured value block =>Page 01-368 , Display group number 003

- Check wire between contact 2/30 on additional relay carrier of brake light suppression relay -J508- and vehicle earth


0.0 - 0.5 V

- Depress brake pedal

approx. battery voltage

- Adjusting brake light switch
=> Brake system; Repair group 46; Brake pedal - Assembly overview; Adjusting brake light switch
Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 28a: Continued on next page.

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

28a

-

Wiring for brake light suppression relay -J508

▪ Ignition switched off
▪ Set to measuring range 200 ω
Pull brake light suppression relay -J508 off additional relay carrier

- Disconnect multi-pin connection T47 from control unit -J104

- Connect test box V.A.G 1598/33

- Check wiring for open circuit between additional relay carrier of brake light suppression relay -J508 and multi-pin connector of control unit -J104:

max. 1.5 ω

- Check wiring using current flow diagram
=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Test step 28a: Continued on next page.

Continuation of test step 28a

Switch to measuring range:
Resistance measurement (200 ω/20 M ω)

Test step

V.A.G 1598 sockets

Item tested

▪ Test conditions
- Additional operations

Specification

Measures for deviations from specification

28a

▪ Set to measuring range 20 M ω

- Remove fuse SB 8

- Check wiring for short circuit to positive or earth



∞ ω

- Check wiring using current flow diagram

=> Current flow diagrams, Electrical fault finding and Fitting locations binder

Definitions > < Test table (test steps 1 - 16)