| First pull breather hose -1- from active charcoal cannister on active charcoal cannister solenoid valve 1 -N80--2-. |
–
| Connect hand-operated vacuum pump VAS 6213 as shown to hose -1-. |
–
| Operate hand-operated vacuum pump V.A.G 6213 several times. Vacuum must not build up. |
–
| Check breather opening -3- located on bottom of active charcoal filter -4- for soiling, clean if necessary. |
If vacuum does not build up: |
–
| Temporarily seal breather opening -3- and operate vacuum pump again several times. A vacuum must build up. |
If vacuum does not build up: |
–
| Renew active charcoal filter. |
|
|
|