| Connect injector to injectors test equipment. |
–
| Slightly push pump lever downwards. When injection starts, read injection pressure. If pressure is different from nominal value, replace injector. |
Theoretical value: (overpressure) New injectors: 220 ... 230 bar Wear limit: 190 bar |
|
|
|