Magnetic valve for refrigerant fluid circulation N43 > < High pressure sensor G65
Pressure and temperature sensor for the refrigerant gasG395
Pressure and temperature sensor for the refrigerant gas -G395-
  WARNING
Freezing Hazard.
If the refrigerant gas loop is not empty, spillages will occur.
The refrigerant gas must be sucked out before disassembling the Pressure and temperature sensor for the cooling gas -G395-. If the refrigerant gas loop is not opened within 10 minutes after suction, pressure may build up in the loop due to later evaporation. Suck the refrigerant gas out once more.
   
ThisPressure and temperature sensor for the refrigerant gas -G395- is assembled as a replacement for theHigh pressure sensor -G65- or the Air conditioning pressure switch -F129 -.
The pressure signal is permanently verified, whereas the temperature signal is only accessed at temperatures above 0 °C.
The Climatronic control unit -J255- operates based on those values, activating the refrigerant liquid fan and the Adjustment valve for the air conditioning compressor -N280-as needed.