volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Command cables - remove and install > < Ventilation / air conditioning adjustment mechanism power connectors (Climatic)
Ventilation / air conditioning adjustment mechanism power connectors (Climatronic)
Ventilation / air conditioning adjustment mechanism power connectors (Climatronic)
For vehicles equipped with Air conditioning system (Climatronic):
t  Vehicles with heating system → Chapter.
t  Vehicles with Air conditioning system → Chapter.
t  Vehicles with Air conditioning system (Climatic) → Chapter.
Removal and installation of ventilation control unit → Chapter.
   
Position of multiple connector (A, B and C) on rear part of heating and air conditioning adjustment (Climatronic):
- A- Housing for 12-pole supply connector.
-1- K-Bus.
-3-Air conditioning adjustment and control unit -J127-.
-4- Fan return information (-).
-5- Fan return information (+).
-8-Sun irradiation photo sensor -G107-.
-9- CAN High (optional).
  N87-0669
-10- CAN Low (optional).
- B- Housing for 20-pole supply connector.
-1-Control motor for temperature adjustment valve -V68-.
-2-Control motor for temperature adjustment valve -V68-.
-3-Defrost valve control motor -V107-.
-4-Defrost valve control motor -V107-.
-5- Earth (-).
-6-Defrost valve control motor for feet region -V85-.
-7-Defrost valve control motor for feet region -V85-.
-8-Control motor for fresh air valve and recirculation valve -V154-.
-9-Control motor for fresh air valve and recirculation valve -V154-.
-11-Air outlet temperature sensor for the central baffle -G191-.
-12-Air outlet temperature sensor for the footwell -G192-.
-14- + 5V 10 mA for control motor potentiometer.
-15-Air outlet temperature sensor for the evaporator -G263-.
-16-Temperature adjustment valve control motor potentiometer -G92-.
-17-Air defrost diffuser valve control motor potentiometer -G135-.
-18-Diffuser and defrost valve control motor potentiometer in feet region -G114-.
  N87-0669
-19-Air recirculation adjustment valve control motor potentiometer -G143-.
- C- Housing for 16-pole supply connector.
-1- + 5V 10 mA for control motor potentiometer.
-2- Earth (-).
-4-Adjustment valve for the air conditioning compressor -N280-.
-7-High pressure sensor -G65- .
-8-Radiator fan control unit -J293-.
-9-Radiator fan control unit -J293-.
-12- Terminal 30.
-13- Terminal 31.
-14- Terminal 31.
-15- Terminal 15.
  N87-0669

Command cables - remove and install > < Ventilation / air conditioning adjustment mechanism power connectors (Climatic)