Engine Control Module: Testing and Inspection
Voltage Supply, Checking

Voltage Supply, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring Diagram.

Test requirements

-

Fuse SA1 OK.

-

Fuse SB23 OK.

-

Fuse SB28 OK.

-

The Ground (GND) connections at the engine and transmission OK.

-

The battery voltage at least 12.5 V.

-

The generator OK.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

If the manufacturers test box is being used. Perform the following step.

-

Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) J623.

Checking voltage supply

-

Using a Multimeter, check the following wiring connection for voltage.

Motronic Engine Control

Measure to

Module (ECM) J623 electrical
harness connector terminal or
test box socket
T121/62

Engine Ground (GND)

Specified value: 12.5 V

If the specified value was not obtained:

-

Check the Motronic Engine Control Module (ECM) J623 electrical harness connector T121 terminal 62 to Battery A Positive for an open circuit
or short to Ground (GND).

-

Check the electrical harness connectors for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

-

Switch the ignition on.

-

Using a Multimeter, check the following wiring connection for voltage.

Motronic Engine Control

Measure to

Module (ECM) J623 electrical
harness connector terminal
or test box socket
T121/3

Engine Ground (GND)

Specified value: 12.5 V

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the Motronic Engine Control Module (ECM) J623 electrical harness connector T121 terminal 3 to the Power Supply Relay (terminal 30,
B+) J317 socket 87 for an open circuit or short to Ground (GND).

CAN-BUS Terminal Resistance, Checking|Page 2446 > < CAN-BUS Terminal Resistance, Checking|Page 2444