background image

-

Remove the right vehicle floor cover - arrows -.

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130 electrical harness connector - 2 -.

-

Switch the ignition on.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130 electrical harness connector terminals 3
to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130. If the specified value was not obtained:

Checking wiring

If the specified value was not obtained:

If the manufacturers test box is being used. Perform the following step.

-

Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) J623.