Rabbit L5-2.5L (BGP) (2006)
Air Door Actuator / Motor: Service and Repair
Heating and Ventilation System
Fresh/Recirculating Air Door Motor V154, Removing and Installing
Fresh/Recirculating Air Door Motor V154, Removing And Installing
Removing:
CAUTION:
-
Switch off all electrical consumers.
-
Switch ignition off and remove ignition key.
NOTE: Position of recirculating air door must not be changed.
-
Remove glove compartment
-
Remove cover -1-
-
Disconnect electrical connection from Fresh/Recirculating Air Door Motor V154 -2-.
-
Remove Fresh/Recirculating Air Door Motor V154 -2- from mounting.
Installing
Install in reverse order of removal, noting the following:
NOTE: Always check Fresh/Recirculating Air Door Motor V154 and recirculating air door function after replacing motor.
-
Checking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault
Finding".
Air Distribution Flap Adjustment Unit, Removing and Installing
Air Distribution Flap Adjustment Unit, Removing And Installing
Removing:
CAUTION:
-
Switch off all electrical consumers.
-
Switch ignition off and remove ignition key.
-
Remove instrument panel
-
Unclip flex cable