Rabbit L5-2.5L (BGP) (2006)
12
-
Suspended mount
-
Replace if damaged
Installation position of clamp
-
Arrow - points in direction of travel.
-
Align clamp - 1 - to marking on catalytic converter - 2 - .
-
- a - = 5 mm
Mounting bolts must not project beyond lower edge of the clamp.
Harness connector for oxygen sensor - installation position
Harness connector is located at right on vehicle floor under cover.
1. Bracket
2. Harness connector for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130 , brown