NOTE:  Thread of shear bolts is equipped with locking compound. By heating the shear bolts using a hot air gun, inhibition effect of the locking
compound is lowered.

CAUTION: Cover wires, harness connectors and control modules in the close vicinity of Engine Control Module (ECM) to prevent
damage from burning.

Perform adjustments on hot air gun - 4 - as shown:

-

Turn potentiometer for temperature adjustment - 2 - to maximum heat output (600 degrees C).

-

Move two stage switch for air quantity - 3 - to position 3.

CAUTION:  By heating the shear bolts, parts of the protective housing are heated intensely. Wear protective gloves to prevent injuries.

-

Guide nozzle of hot air gun on to shear bolts.

-

Switch heat gun on and warm bolts.

-

Remove bolts using locking pliers .

NOTE:  If bolts cannot be removed, saw into heads of shear bolts so that two parallel surfaces are formed - arrows - and then unscrew them.

-

Insert a screwdriver - A - between protective housing and retaining plate - arrow - .