Rabbit L5-2.5L (CBUA) (2008)
1
-
Screws
-
10 ± 1 Nm
-
Qty. 2
2
-
Refrigerant lines on expansion valve
3
-
O-ring
-
13.7 mm; 2.5 mm
4
-
Expansion Valve
-
Removing:
-
Extract refrigerant e.g. using A/C service station VAS 6007A.
CAUTION:
-
There is a danger of ice-up.
-
Refrigerant leaks out if refrigerant circuit is not discharged.
-
Refrigerant must be extracted before opening refrigerant circuit. If refrigerant circuit is not opened within 10 minutes of
extraction, pressure may form in refrigerant circuit due to evaporation. Extract refrigerant once more.
-
Remove screws - 1 - and disconnect refrigerant lines - 2 - from expansion valve.
-
Remove screws - 8 - and remove expansion valve - 4 -.
5
-
O-ring
-
14 mm; 1.82 mm
-
Coat with refrigerant oil when installing
6
-
O-ring
-
10.8 mm; 1.82 mm
-
Coat with refrigerant oil when installing
7
-
O-ring
-
9.5 mm; 2.5 mm
8
-
Cylindrical combination bolt
-
5 Nm