Ignition Control Module: Testing and Inspection

  Check the ignition control unit function by providing it with a simulated Hall generator signal.  If the control unit does not respond correctly, it is
defective and should be replaced.

1.

With the ignition OFF, connect a multimeter to terminals 1 (-) and 15 (+) of the ignition coil.  Do not disconnect harness wires.

 

TCI-H system:

2.

Disconnect the harness connector at the distributor.

3.

Connect a jumper wire to the center terminal of the harness plug.

4.

With the ignition ON, briefly ground the center terminal.  Voltage should increase to at least 2 volts for about 1 - 2 seconds, then drop to 0 volts.

 

TCI-H with knock sensor:

2.

Disconnect the knock sensor control unit harness plug.

3.

Connect a jumper wire to terminal 12 of the harness plug.

4.

With the ignition ON, briefly ground the jumper wire.  Voltage should increase to at least 2 VDC for about 1 - 2 seconds, then drop to 0 VDC.

 

Digifant II:

2.

Disconnect the injection control unit harness plug.

3.

Connect a jumper wire to terminal 25 of the harness plug.

4.

With the ignition ON, briefly ground the jumper wire.  Voltage should increase to at least 2 VDC for about 1 - 2 seconds, then drop to 0 VDC.