Touareg V10-5.0L DSL Turbo (BKW) (2004)
Jump Starting: Service and Repair
Jump Start Point, through 04.05
Jump Start Point, through 04.05
Special tools, testers and auxiliary items required
‹› Torque Wrench (V.A.G 1331/)
Removing
CAUTION!
When disconnecting and connecting the battery, always perform the work procedure as described in the repair information --> [ Battery,
One-Battery Layout, Disconnecting and Connecting ] See: Service and Repair/Removal and Replacement/Battery, One-Battery Layout,
Disconnecting and Connecting. Not adhering to sequence will result in the deactivation of Main Battery Switch -E74- and subsequent
damage to electrical system components.
-
Disconnect battery --> [ Battery, One-Battery Layout, Disconnecting and Connecting ] See: Service and Repair/Removal and
Replacement/Battery, One-Battery Layout, Disconnecting and Connecting.
-
Fold up cover - 1 -.
‹› The illustrations show the external starting point on the V6 Touareg. Vehicles with other engines have only two lines connected.
-
Remove mounting nuts - arrows - and remove connected lines from connector threads.
-
Fold cover up - 3 -, remove mounting nut - 2 - and remove line - 1 - from connector threads.