volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

EGR Control Solenoid|Testing and Inspection|Page 3233 > < EGR Control Solenoid|Testing and Inspection|Page 3231
Page 4
background image

If no malfunctions are found in wires:

-

Replace Engine Control Module (ECM) (J623) --> [ Engine Control Modules, Replacing ] See: Computers and Control Systems/Testing and
Inspection/Component Tests and General Diagnostics/Engine Control Modules, Replacing.

Exhaust Gas Recirculation Valve  2 N213, Test Sequence

-

Disconnect 2-pin connector at Valve 2 for EGR (N213) (- B -)..

-

Measure resistance between terminals of valve.

Specified value: 14.0...20.0 ohms

‹› Resistance at room temperature is in lower specified range, resistance  at operating temperature is in upper specified range.

If specified value is not obtained:

-

Replace Valve 2 for EGR (N213).

-

Erase DTC memory of Engine Control Module (ECM) --> [ Diagnostic Mode 04 - Erase DTC Memory ] .

-

Generate readiness code --> [ Readiness Code ] See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes. 

If specified value is obtained:

-

Switch ignition on.

EGR Control Solenoid|Testing and Inspection|Page 3233 > < EGR Control Solenoid|Testing and Inspection|Page 3231