volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Service and Repair
Page 2
background image

Refrigerant leaks out if refrigerant circuit is not discharged.

Refrigerant must be extracted before opening the refrigerant circuit.  If the refrigerant circuit is not opened within 10 minutes after
extracting  it, pressure may build up in the circuit again. The refrigerant must be extracted  again.

-

Extract refrigerant e.g. using A/C Service Station (VAS 6007A).

-

Observe notes, refer to --> [ Engine Compartment Refrigerant Circuit Components, 2 Zone and 4 Zone ] See: Description and Operation/Engine
Compartment Refrigerant Circuit Components, 2 Zone and 4 Zone. 

-

Remove bumper cover. 

-

Remove bumper carrier. 

Depending on engine, be careful of auxiliary cooler in front of condenser. 

-

Loosen the refrigerant lines at the bolts - 4 -. 

-

Loosen the clips from the radiator mount - 1 -.

-

Swivel condenser upward out of lock carrier.