volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Solar Cell, HVAC > < Evacuating and Charging Valve, Low Pressure Side
Page 1
background image

Service Port HVAC: Service and Repair
Evacuating and Charging Valve, High Pressure Side

Refrigerant Circuit

Evacuating and Charging Valve, High Pressure Side

Special tools, testers and auxiliary items required

‹› Extract refrigerant e.g. using A/C Service Station (VAS 6007A).

‹› Torque Wrench (V.A.G 1783) 

‹› Ratchet Insert 1/4"" (VAS 6234)

‹› Evacuating and charging valve adapter set

Removing

CAUTION!
There is a danger of ice-up.

Refrigerant leaks out if refrigerant circuit is not discharged.

Refrigerant must be extracted before opening the refrigerant circuit.  If the refrigerant circuit is not opened within 10 minutes after
extracting  it, pressure may build up in the circuit again. The refrigerant must be extracted  again.

-

Extract refrigerant circuit, e.g. using A/C Service Station  (VAS 6007A), only then open the refrigerant circuit.

-

Observe notes, refer to --> [ Engine Compartment Refrigerant Circuit Components, 2 Zone and 4 Zone ] See: Description and Operation/Engine
Compartment Refrigerant Circuit Components, 2 Zone and 4 Zone. 

1

Connection with internal thread

2

O-Ring 10.8 mm; 1.8 mm

3

Extraction and filling valve (10 -2 Nm) with  groove and internal thread for cap.

4

O-Ring 10.8 mm; 1.8 mm

5

Cap

Solar Cell, HVAC > < Evacuating and Charging Valve, Low Pressure Side