Note:

^

No one must be in the passenger compartment.

^

Observe the instructions on the cleaner and the cleaning fluid

^

The vehicle must not be exposed to the sun

^

Remove the pollen filter in the passenger compartment (if equipped)

1. The vehicle should be cool, if necessary cool it down with the air conditioning to about 72°F

2. Dry the evaporator by running the ventilation (air conditioning "OFF" at the highest blower level for about 30 minutes.

3. Remove the activated carbon filter or pollen filter according to the repair manual. Close the cover on the AC duct without filter.

4. Open all vents, align them to the passenger compartment and select them with the control panel.

5. Leave the air conditioning switched off. Set the fan speed to level 1 and switch on the circulation air operation. Run the engine during the complete

cleaning process or switch on the ignition and connect a battery charger.

6. Remove the neck (long black pipe) of air conditioning cleaner VAS 61 89a and fill with a bottle of cleaning fluid part number 30208 (observe

instructions on bottle).

7. Place the air conditioning cleaner on the floor underneath the passenger glove box and point the neck towards the front of vehicle (see illustration).

8. Route the cable of cleaner through the side window to the outside. Close the side window and connect the power cable. A self-test starts; when a