volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Variable Induction Control Module|Testing and Inspection|Page 3284 > < Variable Induction Control Module|Testing and Inspection
Page 2
background image

‹› Throttle Drive Angle Sensor 2 (for Electronic Power Control  (EPC)) (G188)

Function test

-

Connect the scan tool.

-

Switch ignition on.

-

Using the scan tool, check the throttle valve position (absolute)  at idle stop:

-

Slowly depress the accelerator pedal to Wide Open Throttle (WOT)  stop while observing the percentage display. The percentage display must
increase  uniformly.

-

Using the scan tool, check the throttle valve position (absolute)  at Wide Open Throttle (WOT) stop:

-

End diagnosis and switch ignition off.

If the specified values are not obtained:

-

Remove the Throttle Valve Control Module (J338 ) far enough so that the electrical connector terminals are reached. 

-

Disconnect the Throttle Valve Control Module (J338) electrical harness connector - arrow -.

Checking resistance

-

Using a multimeter, check the Throttle  Drive (for Electronic Power Control (EPC)) (G186) at the Throttle Valve Control Module (J338) terminals
3 to  5 for resistance.

Variable Induction Control Module|Testing and Inspection|Page 3284 > < Variable Induction Control Module|Testing and Inspection