Page 2
background image

Start diagnosis

Function test

-

Connect scan tool.

-

Start the engine and let it run at idle.

-

Select "Diagnostic mode 6: Check test results of components  that are not continuously monitored".

-

Select "Test-ID 01: Oxygen sensor monitoring before catalytic  converter".

-

Select "Test-ID 131: Dynamic test".

-

Check the specified values at idle.

If the specified values are obtained:

-

End diagnosis and switch ignition off.

If the specified values are not obtained:

Start diagnosis

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic  Converter (TWC) (G130) electrical harness connector -  1 -.

Checking primary voltage

-

Switch the ignition on.

-

Using a multimeter, check the Oxygen  Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector
terminals 3 to 4 for voltage.

Heated Oxygen Sensor 2, Checking|Page 2323 > < Heated Oxygen Sensor 2, Checking|Page 2321