volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor 2, Checking|Page 2345 > < Heated Oxygen Sensor 2, Checking|Page 2343
Page 17
background image

Specified value: 1.5 ohms max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+),  and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose  or broken terminals.

-

If necessary, repair the faulty wiring connection.

-

Erase the DTC memory.  Refer to --> [ Diagnostic Mode 04 - Erase DTC Memory ] See: Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 04 - Erase DTC Memory

-

Perform a road test to verify repair.

If the DTC does not return:

Repair complete, Generate readiness code. Refer to --> [ Readiness Code ] See: Computers and Control Systems/Testing and Inspection/Monitors,
Trips, Drive Cycles and Readiness Codes.

-

End diagnosis.

If the DTC does return and no malfunction is detected in the wiring  and the voltage supply was OK:

-

Replace the Motronic Engine Control Module (ECM) (J623). 

-

Assembly is performed in the reverse of the removal.

Final procedures

After repair work, the following work steps must be performed in the  following sequence:

1. Check the DTC memory. Refer to --> [ Diagnostic Mode 03 - Read DTC Memory ] See: Computers and Control Systems/Testing and

Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 03 - Read DTC Memory. 

2. If necessary, erase the DTC memory. Refer to --> [ Diagnostic Mode 04 - Erase DTC Memory ] See: Computers and Control Systems/Testing and

Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 04 - Erase DTC Memory.

3. If the DTC memory was erased, generate readiness code. Refer to --> [ Readiness Code ] See: Computers and Control Systems/Testing and

Inspection/Monitors, Trips, Drive Cycles and Readiness Codes.

-

End of diagnosis.

Oxygen Sensor O2S 2 behind Three Way Catalytic Converter TWC Heater, Checking

Oxygen Sensor O2S 2 behind Three Way Catalytic Converter TWC Heater, Checking

The following procedure is used to diagnose Oxygen Sensor  (O2S) 2 (behind Three Way Catalytic Converter (TWC)) Heater (Z30) for Oxygen
Sensor (O2S) 2 Behind Three Way Catalytic  Converter (TWC) (G131).

‹› When servicing terminals in harness connector of Oxygen Sensor  (O2S) Behind Three Way Catalytic Converter (TWC) (G131) use  only

gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Heated Oxygen Sensor 2, Checking|Page 2345 > < Heated Oxygen Sensor 2, Checking|Page 2343