‹› A second technician is needed for the following task.
-
Connect Pressure Gauge with adapter , as shown.
-
However, do not connect ends of Hose to fuel rail connector.
-
Hold end of Hose in a measuring container.
-
Open shut-off valve of pressure gauge. The lever points in direction of flow.
-
Switch ignition on.
-
Operate Hand held remote starter (jumper). Slowly close shut-off tap, until pressure gauge shows 4 bar fuel pressure. From this point on do not
move position of shut-off tap.
-
Do not operate Hand held remote starter (jumper) any more.
-
Empty measuring container.
-
Operate remote control for 15 seconds.
-
Compare quantity of fuel delivered with minimum delivery rate in diagram (cm3/15s).
‹› Voltage at fuel pump with engine stopped and pump running is approx. 2 volts less than battery voltage.
If minimum delivery rate is not attained:
-
Check fuel lines for possible restrictions (kinks) or blockages.