Touareg 2 V6-3.6L (BHK) (2008)
Wiring Harness: Procedures
Contact Surface Cleaning Set VAS 6410
Protecting
CAUTION!
Missing protection leads to the electrical system damage.
‹› All threaded connections must be tightened to the specified torque.
‹› When applying protection, always use the accompanying hose on the protection container.
‹› Protection wax is used in the cool area.
‹› Cavity protection wax is used in the warm area.
‹› The protection material draws itself into the affected places by capillary action.
-
Hold the injector under the wiring eyelet and spray all around the pins.
-
Hold the injector above the wiring eyelet and spray all around the pins and wiring eyelet.
Battery Terminal Clamp and Battery Terminal, Cleaning
Special tools, testers and auxiliary items required
‹› Torque Wrench (VAG 1331)