t
| The quick-release coupling adapter for service connection can be fitted with a modified charging hose -A- (e.g. with a 5/8"-18 UNF thread, depending on the thread of the quick-release coupling adapter) and a suitable adapter -B- to connect to the workshop compressed air system → Chapter. To ensure no moisture, oil or other contaminants can enter the refrigerant circuit from the workshop compressed air system, use, for example, a supplementary combination fine filter element with an oil, dirt and water separator as normally used in paint shops. Install it between the compressed air system and the charging hose -A- → Workshop equipment catalogue. |
|
|
|