Vanagon F4-1915cc 1.9L (Water Cooled) (1983)
-
Touch center wire of connector on distributor briefly to ground
Indicated voltage must drop briefly below 3 volts
-
Connect multimeter to outer terminals of Hall generator connector
-
Turn ignition ON
Spec. = 5 volts (min)
Note: If readings are within specifications, but defect still exists, replace Hall control unit or check for wire breaks between Hall generator connector
and Hall control unit; if necessary, repair.
Note:
Metal shavings or other debris between the ignition control unit and heat sink can cause stress which may damage internal circuits of the control
unit:
When replacing ignition control unit, thoroughly clean heat sink before assembly.