Vanagon F4-1970cc 2.0L (1982)
Ignition Control Module: Testing and Inspection
Hall Control Unit, Checking
Hall control unit, checking
Work sequence
Test condition:
ignition coil OK, ignition OFF
-
disconnect both plugs from idle stabilizer and connect them together (arrow)
-
remove connector from Hall control unit
-
connect voltmeter with + (plus) to terminal 4 and with - (minus) to terminal 2 in connector
-
turn ignition ON
spec = approx. battery voltage
if not, check for wire breaks and repair (see wiring diagram)
-
turn ignition OFF
-
reconnect connector to Hall control unit
-
disconnect Hall generator connector from ignition distributor