Control Module HVAC: Testing and Inspection
Fan Control Module

To check the blower control unit:

-

Remove electrical connector from control head panel

-

Turn ignition "ON".

-

Check for power at terminal 1 of blower control unit.

-

Check for ground at terminal 5 of blower control unit.

-

Connect test light between terminals 1 and 6. (Do not use a jumper wire).

^

blower motor should run.

-

Connect test light between terminals 5 and 6.

^

blower should not run. If blower runs, replace blower control.

-

Remove connector from blower control unit and connect wires on connector from terminals 1 and 6 with jumper wire.

^

blower motor should run. If not, replace blower motor.

Terminal

Function

12V (Terminal 15) with ignition on from fuse 17

3

Power output to blower

5

Ground

6

Input signal from control panel head used to activate and control blower motor speed. Voltage ranges from approximately 2
volts in LO fan speed to 6 volts in HI fan speed.