audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Accelerator Linkage - Automatic Transmission|Page 521 > < Accelerator Linkage - Automatic Transmission|Page 519
Page 1
background image

Throttle Cable/Linkage: Adjustments
Cold Start Advance

Injection pump lever must be against idle stop
To accomplish this:

Either slacken tension on cold start acceleration cable or bring engine to operating temperature, oil @ 70°C minimum, (158°F) 

-

Attach pivot lever to support using a 3.5 mm (0.138 in) pin

-

Loosen adjustment screw (2) on linkage

-

Adjust linkage length such that ball ends on pivot and injection pump levers can be mounted free of tension

Accelerator Linkage - Automatic Transmission|Page 521 > < Accelerator Linkage - Automatic Transmission|Page 519