audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fault table; fault code 01317 - 01701 > < Fault table for convenience system
Body Self-diagnosis
Fault table for convenience system
Fault table; fault code 00000 - 01134

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00000

No faults detected

If "No fault detected" appears after performing repairs, self-diagnosis is ended.

00892

Release switch -F248, tailgate lock cyl.

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Release switch -F248 for tailgate lock cylinder defective

- Check and if necessary replace release switch -F248 for tailgate lock cylinder

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00912

Switch -E40 for FL window lifter

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 011 , Display zone 1

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E40 for FL window lifter defective

- Replace the switch for window lifter and mirror adjustment

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00913

Switch for FR driver's side window lifter -E81

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 012 => Page 01-58, Display zone 1

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch for FR driver's side window lifter -E81 defective

- Replace the switch for window lifter and mirror adjustment

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00914

Switch -E53 for RL driver's side window lifter

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 012 => Page 01-58, Display zone 3

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E53 for RL window lifter defective

- Replace the switch for window lifter and mirror adjustment

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00915

Switch -E55 for RR driver's window lifter

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 012 => Page 01-58, Display zone 2

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E55 for RR window lifter defective

- Replace the switch for window lifter and mirror adjustment

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00932

Motor -V147 for driver's side window lifter

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Window lifter mechanism stiff1)

- Check and ensure free movement of window lifter

- Motor -V147 for driver's side window lifter stiff or defective (CL relay adhesive, Hall sender defective)

- Replace door control unit, driver's side -J386

No or wrong setting

- Initialisation of automatic open/close function not performed

- Perform initialisation of automatic open/close function

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00933

Motor -V148 for passenger's side window lifter

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Window lifter mechanism stiff1)

- Check and ensure free movement of window lifter

- Motor -V148 for passenger's side window lifter stiff or defective (CL relay adhesive, Hall sender defective)

- Replace door control unit, passenger's side -J387

No or wrong setting

- Initialisation for automatic open/close function not performed

- Perform initialisation for automatic open/close function

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00934

Motor -V26 for RL window lifter

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Window lifter mechanism stiff1)

- Check and ensure free movement of window lifter

- Motor -V26 for RL window lifter stiff or defective (CL relay adhesive, Hall sender defective)

- Door control unit, rear left -J388

No or wrong setting

- Initialisation for automatic open/close function not performed

- Perform initialisation for automatic open/close function

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00935

Motor -V27 for RR window lifter

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Window lifter mechanism stiff1)

- Check and ensure free movement of window lifter

- Motor -V27 for RR window lifter stiff or defective (CL relay adhesive, Hall sender defective)

- Replace door control unit, rear right -J389

No or wrong setting

- Initialisation for automatic open/close function not performed

- Perform initialisation for automatic open/close function

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00936

Switch -E107 for pass. side window lifter1)

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 014 => Page 01-61, Display zone 1

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E107 for pass. side window lifter defective

- Replace switch -E107 for pass. side window lifter and mirror adjustment

1)    A fault is set if the rocker switch is pressed in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00937

Switch -E52 for RL window lifter1)

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 015 => Page 01-62, Display zone 3

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E52 for RL window lifter defective

- Replace switch -E52 for RL window lifter

1)    A fault is set if the rocker switch is pressed in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00938

Switch -E54 for RR window lifter1)

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Read measured value block; display group 015 => Page 01-62, Display zone 1

- Installation of the switch NOK, sticks when operated

- Check the switch

- Switch -E54 RR window lifter defective

- Replace switch -E54 RR window lifter

1)    A fault is set if the rocker switch is operated in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00939

Motor -V149 for mirror adjust., driver's side

Short to positive
Short to earth

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Motor -V149 for mirror adjust., driver's side defective

- Check and if necessary replace motor -V149 for mirror adjust., driver's side.

00940

Motor -V150 for mirror adjust., passenger's side

Short to positive
Short to earth

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

- Motor -V150 for mirror adjust., passenger side defective

- Check and if necessary replace motor -V150 for mirror adjust., pass. side.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00952

Signal driver's door open

Short to positive

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

00947

Switch -E188 for remote unlocking, tailgate

Implausible signal

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram

- Switch -E188 for remote unlocking, tailgate is defective

- Check and if necessary replace switch -E188 for remote unlocking, tailgate.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00955

Key 1

Adaption limit exceeded

- Key was operated more than 200 times while out of range

- Re-matching procedure for existing radio-operated remote control keys => Page

00956

Key 2

Adaption limit exceeded

00957

Key 3

Adaption limit exceeded

00958

Key 4

Adaption limit exceeded

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

00964

Signal for driver's door open; positive

Short to positive
Short to earth

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

01030

Driver's side CL key switch, lock

Implausible signal1)

- Fault in wiring or connectors
- Lock cylinder sticks

- Check wiring and connectors according to current flow diagram

1)    Is set if operated for longer than 1 minute (switch stuck).

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01031

Driver's side CL key switch, unlock

Implausible signal1)

- Fault in wiring or connectors
- Lock cylinder sticks

- Check wiring and connectors according to current flow diagram

1)    Is set if operated for longer than 1 minute (switch stuck).

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01032

Passenger's side CL key switch, lock

Implausible signal1)

- Fault in wiring or connectors
- Lock cylinder sticks

- Check wiring and connectors according to current flow diagram

1)    Is set if operated for longer than 1 minute (switch stuck).

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01033

Passenger's side CL key switch, unlock

Implausible signal1)

- Fault in wiring or connectors
- Lock cylinder sticks

- Check wiring and connectors according to current flow diagram

1)    Is set if operated for longer than 1 minute (switch stuck).

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01034

Window lifter thermal protection active, driver's side

- Fault in wiring or connectors
- Window lifter sticks or is stiff1)
- Window lifter motor stiff
- Thermal protection software has triggered

- Erasing fault memory => Page

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01035

Window lifter thermal protection active, passenger's side

- Fault in wiring or connectors
- Window lifter sticks or is stiff1)
- Window lifter motor stiff
- Thermal protection software has triggered

- Erasing fault memory => Page

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01036

Window lifter thermal protection active, RL

- Fault in wiring or connectors
- Window lifter sticks or is stiff1)
- Window lifter motor stiff
- Software thermal protection has triggered

- Erasing fault memory => Page

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01037

Window lifter thermal protection active, RR

- Fault in wiring or connectors
- Window lifter sticks or is stiff1)
- Window lifter motor stiff
- Software thermal protection has triggered

- Erasing fault memory => Page

1)    The door window may also run stiffly in the window channel.

Output on printer
V.A.G 1551

Possible causes of fault

Fault remedy

01134

Alarm horn -H12

Short to positive
Short to earth

- Fault in wiring or connectors

- Check wiring and connectors according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Internal voltage supply

- Fuses defective
- No voltage supply

- Check fuses and replace if necessary
Check power supply

No communication1)
Defective1)

- Open or short circuit in the signal wire from backup horn to convenience system central control unit.
- Alarm horn -H12 defective

- Check and if necessary repair wiring from backup horn to convenience system central control unit

1)    Vehicles with intelligent backup horn only.

Fault table; fault code 01317 - 01701 > < Fault table for convenience system