Fault table for convenience system
Fault table; fault code 00000 - 01134
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00000
|
|
|
No faults detected
|
If "No fault detected" appears after performing repairs, self-diagnosis is ended.
|
00892
|
|
|
Release switch -F248, tailgate lock cyl.
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Release switch -F248 for tailgate lock cylinder defective
|
- Check and if necessary replace release switch -F248 for tailgate lock cylinder
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00912
|
|
|
Switch -E40 for FL window lifter
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 011 , Display zone 1
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E40 for FL window lifter defective
|
- Replace the switch for window lifter and mirror adjustment
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00913
|
|
|
Switch for FR driver's side window lifter -E81
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 012 => Page 01-58, Display zone 1
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch for FR driver's side window lifter -E81 defective
|
- Replace the switch for window lifter and mirror adjustment
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00914
|
|
|
Switch -E53 for RL driver's side window lifter
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 012 => Page 01-58, Display zone 3
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E53 for RL window lifter defective
|
- Replace the switch for window lifter and mirror adjustment
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00915
|
|
|
Switch -E55 for RR driver's window lifter
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 012 => Page 01-58, Display zone 2
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E55 for RR window lifter defective
|
- Replace the switch for window lifter and mirror adjustment
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00932
|
|
|
Motor -V147 for driver's side window lifter
|
|
|
|
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Window lifter mechanism stiff1)
|
- Check and ensure free movement of window lifter
|
|
- Motor -V147 for driver's side window lifter stiff or defective (CL relay adhesive, Hall sender defective)
|
- Replace door control unit, driver's side -J386
|
|
No or wrong setting
|
- Initialisation of automatic open/close function not performed
|
- Perform initialisation of automatic open/close function
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00933
|
|
|
Motor -V148 for passenger's side window lifter
|
|
|
|
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Window lifter mechanism stiff1)
|
- Check and ensure free movement of window lifter
|
|
- Motor -V148 for passenger's side window lifter stiff or defective (CL relay adhesive, Hall sender defective)
|
- Replace door control unit, passenger's side -J387
|
|
No or wrong setting
|
- Initialisation for automatic open/close function not performed
|
- Perform initialisation for automatic open/close function
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00934
|
|
|
Motor -V26 for RL window lifter
|
|
|
|
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Window lifter mechanism stiff1)
|
- Check and ensure free movement of window lifter
|
|
- Motor -V26 for RL window lifter stiff or defective (CL relay adhesive, Hall sender defective)
|
- Door control unit, rear left -J388
|
|
No or wrong setting
|
- Initialisation for automatic open/close function not performed
|
- Perform initialisation for automatic open/close function
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00935
|
|
|
Motor -V27 for RR window lifter
|
|
|
|
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Window lifter mechanism stiff1)
|
- Check and ensure free movement of window lifter
|
|
- Motor -V27 for RR window lifter stiff or defective (CL relay adhesive, Hall sender defective)
|
- Replace door control unit, rear right -J389
|
|
No or wrong setting
|
- Initialisation for automatic open/close function not performed
|
- Perform initialisation for automatic open/close function
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00936
|
|
|
Switch -E107 for pass. side window lifter1)
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 014 => Page 01-61, Display zone 1
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E107 for pass. side window lifter defective
|
- Replace switch -E107 for pass. side window lifter and mirror adjustment
|
1) A fault is set if the rocker switch is pressed in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00937
|
|
|
Switch -E52 for RL window lifter1)
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 015 => Page 01-62, Display zone 3
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E52 for RL window lifter defective
|
- Replace switch -E52 for RL window lifter
|
1) A fault is set if the rocker switch is pressed in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00938
|
|
|
Switch -E54 for RR window lifter1)
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 015 => Page 01-62, Display zone 1
|
|
- Installation of the switch NOK, sticks when operated
|
- Check the switch
|
|
- Switch -E54 RR window lifter defective
|
- Replace switch -E54 RR window lifter
|
1) A fault is set if the rocker switch is operated in one direction for longer than 1 minute, or both signals (open, close) occur simultaneously.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00939
|
|
|
Motor -V149 for mirror adjust., driver's side
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Motor -V149 for mirror adjust., driver's side defective
|
- Check and if necessary replace motor -V149 for mirror adjust., driver's side.
|
00940
|
|
|
Motor -V150 for mirror adjust., passenger's side
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
- Motor -V150 for mirror adjust., passenger side defective
|
- Check and if necessary replace motor -V150 for mirror adjust., pass. side.
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00952
|
|
|
Signal driver's door open
|
|
|
|
Short to positive
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
00947
|
|
|
Switch -E188 for remote unlocking, tailgate
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram
|
|
|
- Switch -E188 for remote unlocking, tailgate is defective
|
- Check and if necessary replace switch -E188 for remote unlocking, tailgate.
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00955
|
|
|
Key 1
|
|
|
|
Adaption limit exceeded
|
- Key was operated more than 200 times while out of range
|
- Re-matching procedure for existing radio-operated remote control keys => Page
|
00956
|
|
|
Key 2
|
|
|
|
Adaption limit exceeded
|
|
|
00957
|
|
|
Key 3
|
|
|
|
Adaption limit exceeded
|
|
|
00958
|
|
|
Key 4
|
|
|
|
Adaption limit exceeded
|
|
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
00964
|
|
|
Signal for driver's door open; positive
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
01030
|
|
|
Driver's side CL key switch, lock
|
|
|
|
Implausible signal1)
|
- Fault in wiring or connectors - Lock cylinder sticks
|
- Check wiring and connectors according to current flow diagram
|
1) Is set if operated for longer than 1 minute (switch stuck).
1) Is set if operated for longer than 1 minute (switch stuck).
1) Is set if operated for longer than 1 minute (switch stuck).
1) Is set if operated for longer than 1 minute (switch stuck).
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01034
|
|
|
Window lifter thermal protection active, driver's side
|
|
|
|
|
- Fault in wiring or connectors - Window lifter sticks or is stiff1) - Window lifter motor stiff - Thermal protection software has triggered
|
- Erasing fault memory => Page
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01035
|
|
|
Window lifter thermal protection active, passenger's side
|
|
|
|
|
- Fault in wiring or connectors - Window lifter sticks or is stiff1) - Window lifter motor stiff - Thermal protection software has triggered
|
- Erasing fault memory => Page
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01036
|
|
|
Window lifter thermal protection active, RL
|
|
|
|
|
- Fault in wiring or connectors - Window lifter sticks or is stiff1) - Window lifter motor stiff - Software thermal protection has triggered
|
- Erasing fault memory => Page
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01037
|
|
|
Window lifter thermal protection active, RR
|
|
|
|
|
- Fault in wiring or connectors - Window lifter sticks or is stiff1) - Window lifter motor stiff - Software thermal protection has triggered
|
- Erasing fault memory => Page
|
1) The door window may also run stiffly in the window channel.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01134
|
|
|
Alarm horn -H12
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
Internal voltage supply
|
- Fuses defective - No voltage supply
|
- Check fuses and replace if necessary Check power supply
|
|
No communication1) Defective1)
|
- Open or short circuit in the signal wire from backup horn to convenience system central control unit. - Alarm horn -H12 defective
|
- Check and if necessary repair wiring from backup horn to convenience system central control unit
|
1) Vehicles with intelligent backup horn only.
|