audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Test step 3: > < Test step 2:
Temperature-dependent resistance values of the sensors/senders:
   
Temperature-dependent resistance values of the sensors/senders:
Temperature
measured at the sensor/sender fitting location
Resistance value
of the fresh-air intake duct temperature sensor -G89-
(and of the ambient temperature sensor -G17-)
Resistance value
of the centre vent temperature sender -G191-
and of the footwell vent temperature sender -G192-
Resistance value
of the evaporator outlet temperature sender -G263-
°CKKK
- 3018,10(141,00)(52,20)
- 209,95(85,00)(27,75)
-105,59(47,00)(15,50)
03,2829,009,00
52,5423,206,96
101,9918,605,44
151,5715,004,28
201,2512,203,40
251,0010,002,72
300,808,202,19
350,656,801,78
400,535,701,46
500,364,001,00
600,252,90-

   

Test step 3: > < Test step 2: