The pressure signal from the high-pressure sender G65 > < Checking the pressure signal from the high-pressure sender G65
Pin assignment on the high-pressure senderG65
Pin assignment on the high-pressure sender -G65-
   
Contact -1- Earth
Contact -2 - signal output (square-wave signal to the operating and display unit for air conditioner/Climatronic -E87- and to the engine control unit)
Contact -3-, positive (terminal “75”)
  Note
t  The compressor is not switched on if connector -B- is unplugged.
t  The high-pressure sender -A- is an electronic control unit which generates a square-wave signal with a ratio which varies with the pressure in the refrigerant circuit → Chapter.
  A87-0341

The pressure signal from the high-pressure sender G65 > < Checking the pressure signal from the high-pressure sender G65