A3 L4-2.0L Turbo (CBFA) (2008)
Checking voltage supply, terminal 15
-
Using a multimeter, check the Selector Lever E313 electrical harness connector terminals 9 to 1 for voltage.
Specified value: battery voltage.
If the specified value was not obtained:
-
Check the wiring connection for an open circuit, short circuit to Battery (+) or Ground (GND).
-
Check the wiring connection for damage, corrosion, loose or broken terminals.
-
If necessary, repair the faulty wiring connection.
If the wiring and voltage were OK: Replace the Selector Lever E313.
Final procedures
After the repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Mode 03 - Read DTC Memory
2. If necessary, erase the DTC memory. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing
and Procedures/Diagnostic Mode 04 - Erase DTC Memory
3. If the DTC memory was erased, generate readiness code. See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Monitors, Trips, Drive Cycles and Readiness Codes