Notes:

  • ◆ The following table lists all the faults, with the corresponding 5-digit code numbers, that can be recognised by the central locking control unit and printed out by the V.A.G 1551.
  • ◆ Fault codes appear only on print-out.
  • ◆ Before replacing a component shown as faulty, check wiring and connections to component as well as earth connections according to current flow diagram.
  • ◆ Once repairs have been completed, the fault memory is always to be interrogated again with fault reader V.A.G 1551 and erased. The vehicle is then to be relocked (with key or remote) and the fault memory is re-interrogated.
  • ◆ All static and sporadic faults are stored in the fault memory:
    When a fault occurs it is immediately identified as a static fault. If fault does not occur again it is registered as a sporadic fault. "/SP" appears on the right of the display.
  • ◆ When ignition is switched on, all existing faults are automatically reclassified as sporadic faults and will only register as static faults if they still occur after testing.
  • ◆ Sporadic faults which no longer occur after 50 opening cycles are erased automatically.
  • ◆ The 3-digit fault type number appearing next to the fault code is a data code which can be ignored.

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

00955

Key 1

Adaption limit exceeded

- Key not matched
- Key operated more than 200 times while out of range

- Perform key matching procedure

00956

Key 2

Adaption limit exceeded

- Key not matched
- Key operated more than 200 times while out of range

- Perform key matching procedure
=> Page 01-99

00957

Key 3

Adaption limit exceeded

- Key not matched
- Key operated more than 200 times while out of range

- Perform key matching procedure
=> Page 01-99

00958

Key 4

Adaption limit exceeded

- Key not matched
- Key operated more than 200 times while out of range

- Perform key matching procedure
=> Page 01-99

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

00991

Interior lighting
Short to positive

- Short in wiring or in connections

- Fault finding according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

01360

Open switch for ATW
Short to earth 1)

- Short to earth in the wiring.
- Door contact switch -F2 defective

- Fault finding according to current flow diagram

01361

Close switch for ATW
Short to earth 1)

- Short to earth in the wiring.
- Door contact switch -F2 defective

- Fault finding according to current flow diagram

1)    The fault is stored, if earth is applied for more than 1 minute, e. g. resulting from incorrect operation of the central locking. Only perform the fault remedy procedure if there are malfunctions otherwise simply erase the fault memory .

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01362

Close tailgate switch -F124
Short to earth 1)

- Short to earth in the wiring.
- Switch -F124 defective

- Fault finding according to current flow diagram

01363

Switch for CL, driver door -F59
Implausible signal

- This display can appear depending on the system. Switch -F59 is not defective.

- Ignore fault display and erase the fault memory => Page 01-129

01364

Central locking switch, front passenger door -F114
Implausible signal

- This display can appear depending on the system. Switch -F114 is not defective.

- Ignore fault display and erase the fault memory => Page 01-129

1)    The fault is stored, if earth is applied for more than 1 minute, e. g. resulting from incorrect operation of the central locking. Only perform the fault remedy procedure if there are malfunctions otherwise simply erase the fault memory .

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01365

Lock/unlock internal switch/lock switch
Short to earth 1)

- Short to earth in the wiring.
- Switch -E150 defective

- Fault finding according to current flow diagram

01365

Lock/unlock internal switch/lock switch
Short to positive

- Short in the wiring
- Switch -E150 defective

- Fault finding according to current flow diagram

1)    The fault is stored, if earth is applied for more than 1 minute, e. g. resulting from incorrect operation of the central locking. Only perform the fault remedy procedure if there are malfunctions otherwise simply erase the fault memory .

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01366

Opening via crash signal
Short to earth
Open circuit/short to positive

- Final control diagnosis on airbag control unit -J234 or on control unit for central locking -J429 has been performed
- Airbag control unit -J234 triggered
- Short or open circuit in wiring between airbag control unit and central locking control unit

- Read fault memory of airbag control unit -J234
Delete fault memory => Page 01-129
Check wiring and connections between airbag control unit and central locking control unit according to current flow diagram and repair if necessary
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

01367

Switching off of central locking pump.

- Insufficient pressure in the pneumatic lines.
- Central locking pump defective

- Check pneumatic lines for leaks.

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01368

Alarm from boot switch

- ATW has triggered as a result of unauthorised opening of the tailgate.
- Contact switch in tailgate/boot lid -F123 defective.
- False alarm.

- Erase fault memory

01369

Alarm from bonnet switch

- ATW has triggered as a result of unauthorised opening of the bonnet
- Switch bonnet lid -F120 defective.
- False alarm.

- Erase fault memory

01370

Alarm from interior monitor
Short to earth

- ATW has triggered as a result of interior monitor signal
- Control unit for ultrasonic sensors -J347 defective
- Short circuit in wiring connection between control unit for ultrasonic sensors and CL control unit.
- False alarm.

- Erase fault memory
Fault-finding after self-diagnosis ultrasonic interior monitor=> Page 01-104
Check wiring and connections between ultrasonic sensors control unit and central locking control unit according to current flow diagram and repair if necessary
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01371

Alarm triggered by driver's door contact switch.

- ATW has triggered as a result of unauthorised opening of driver's door.
- Door contact switch -F2 defective
- False alarm.

- Erase fault memory

01372

Alarm triggered by rear door contact switch/ front passenger door.

- ATW has triggered as a result of unauthorised opening of front passenger door and/or rear doors
- Door contact switches -F3, -F10, -F11 defective.
- False alarm.

- Erase fault memory

01373

Alarm from radio earth contact

- ATW has triggered as a result of unauthorised removal of radio.
- Earth connection for ATW is interrupted
- False alarm.

- Erase fault memory
Establish earth connection.

V.A.G 1551 print-out

Possible causes of fault

Fault remedy

01374

Alarm from terminal 15

- ATW has triggered as a result of unauthorised starting (short-circuiting).
- Short-circuit between terminals 30 and 15.
- False alarm.

- Erase fault memory
Fault finding according to current flow diagram
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

01389

Open switch for tailgate -F124.
Short to earth

- Short to earth in the wiring.
- Switch for tailgate -F124 defective.

- Fault finding according to current flow diagram

65535

Control unit defective

- Central locking control unit -J429 defective

- Replace central locking control unit -J429