  Note
Cleaning refrigerant circuit means flushing with refrigerant R134a → Chapter or blowing out with compressed air or nitrogen → Chapter.
For example in the event of accident damage; no refrigerant escaped and no ingress of moisture and dirt into the circuit
–  Discharge refrigerant circuit.
–  Renew restrictor.
–  Remove receiver or reservoir.
–  Remove dirt from receiver or reservoir.
–  Weigh receiver or reservoir removed.
–  Fill the new receiver or reservoir with refrigerant oil until it attains the weight of the vessel removed.
–  Install new receiver or reservoir.
–  Assemble, evacuate and charge refrigerant circuit.
   