audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Test table, part 1 > < Initiating basic setting
Automatic gearbox 01M Self-diagnosis
Reading measured value block
Reading measured value block
  • ‒ Connect fault reader V.A.G 1551, enter address word "02 Gearbox electronics" and advance the programme until "Select function XX" appears in the display => from Page 01-25.
Warning!
Secure fault reader to rear seat and operate from this position. Observe safety precautions Page 01-26
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys 0 and 8. (The function "Read measured value block" is selected with 08.)
 
→ Indicated on display:
Rapid data transfer     Q
08 - Read measured value block
  • ‒ Confirm entry with key Q.
 
→ Indicated on display:
Read measured value block
Enter display group number XXX
  • ‒ Enter Display Group number => List of available Display Group numbers, Page 01-90.
  • ‒ Confirm entry with key Q.
 
→ The measured value block always shows 4 display zones (with physical values where required). For an explanation of values 1 to 4 in the individual display zones =>Test table, Page 01-92.
Read measured value block    1    ⇒
1    2    3    4

List of available Display Group numbers

Readout in display (example)

Display Group No.

Display zone

Designation

Read measured value block
P 0.8 V

1 ⇒

0 % 00000111

001

1
2
3
4

Selector lever position
Voltage of throttle valve control part
Accelerator pedal value
Switch positions

Read measured value block

0.983 A 0.985 A

2 ⇒

12.76 V 2.50 V

002

1
2
3
4

Actual current of solenoid valve 6 -N93
Specified current of solenoid valve 6 -N93
Battery voltage
Voltage at road speed sender-G68

Read measured value block

0 km/h 900 rpm

3 ⇒

0 0 %

003

1
2
3
4

Road speed
Engine speed
Selected gear
Accelerator pedal value

Read measured value block

1010 00 0

4 ⇒

P 0 km/h

004

1
2
3
4

Solenoid valves
Selected gear
Selector lever position
Road speed

Read measured value block

45 °C 0011001

5

0 900 rpm

005

1
2
3
4

ATF temperature
Switch outputs
Gear to select
Engine speed

Readout in display (example)

Display Group No.

Display zone

Designation

Read measured value block

+8 % 35 %

6 ⇒

41 % 60 %

006

1
2
3
4

Can be disregarded at present
Can be disregarded at present
"Sport" factor
Accelerator pedal value

Read measured value block

R 200 rpm

7 ⇒

900 rpm 0 %

007

1
2
3
4

Selected gear
Slip of lock-up clutch
Engine speed
Accelerator pedal value

Read measured value block

8 ⇒

008

Can be disregarded at present

Note:

If the printer is switched on, the current readout in the display is printed out on the test log.

If the specified values are achieved in all the display zones, proceed as follows:

  • ‒ Press key ⇒.
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX

Test table, part 1 > < Initiating basic setting